How it works
Enter the room dimensions and the equivalent absorption area of its surfaces and contents. The Sabine estimate is 0.161 times room volume in cubic metres divided by total absorption in square metres sabin; enter absorption as a total rather than per-surface values.
Worked example
A 6 m × 5 m × 3 m room with 30 m² sabin of total absorption has an estimated RT60 of 0.483 seconds.
Scope and local notes
This version uses metres and square metres sabin, common SI units in UK acoustic work. RT60 targets depend on the room's purpose and applicable project specifications; this calculation does not set a regulatory target.
Frequently asked questions
What does RT60 mean?
It is the estimated time for sound energy to decay by 60 dB after a source stops.
Why is this only an estimate?
The Sabine formula assumes a reasonably diffuse sound field and works best when absorption is not very high or unevenly distributed.