Radiator Size Calculator

Estimate a room radiator output from floor area and insulation, then optionally compare the estimate with the radiator rating.

This calculation runs on your device; inputs are not sent.

Advertisement
How to use this estimate, example and FAQs
  1. Measure the room inside and enter metres.
  2. Choose the closest insulation level. The 50 and 100 W/m² figures are manufacturer examples; 75 is their arithmetic midpoint.
  3. Optionally enter the radiator output from its manufacturer. That rating applies only at its stated flow, return and room temperatures.
  4. Use this as a first indication. For replacement or heat-pump design, ask for a room-by-room heat-loss calculation.

Worked example

A 5 × 4 m room is 20 m². At the average setting (75 W/m²), the rough estimate is 1,500 W. A radiator rated at 1,200 W is 300 W below that indication; first check that the manufacturer rating uses the same water temperatures.

Why is this only an estimate?

A proper heat-loss calculation includes transmission and ventilation/infiltration per room. Floor area and an insulation choice do not provide those details.

Can I size a heat pump with this?

No. Lower flow temperatures reduce radiator output. Use the product output curve and a qualified room-by-room calculation.

How should I compare radiator ratings?

Compare ratings at the same temperature regime, such as 75/65/20 °C. Check the manufacturer test conditions.

What does below estimate mean?

It is a reason to check the room and radiator further, not proof that the radiator is undersized.

Sources: Radson warmteverliescalculator; Radson technische gids (voorbeeld 50/100 W/m²); Milieu Centraal over radiatorafgifte en isolatie.

Translations beyond Dutch and English are drafts and need native review.