Radiator Size Calculator
Estimate a room radiator output from floor area and insulation, then optionally compare the estimate with the radiator rating.
This calculation runs on your device; inputs are not sent.
How to use this estimate, example and FAQs
- Measure the room inside and enter metres.
- Choose the closest insulation level. The 50 and 100 W/m² figures are manufacturer examples; 75 is their arithmetic midpoint.
- Optionally enter the radiator output from its manufacturer. That rating applies only at its stated flow, return and room temperatures.
- Use this as a first indication. For replacement or heat-pump design, ask for a room-by-room heat-loss calculation.
Worked example
A 5 × 4 m room is 20 m². At the average setting (75 W/m²), the rough estimate is 1,500 W. A radiator rated at 1,200 W is 300 W below that indication; first check that the manufacturer rating uses the same water temperatures.
Why is this only an estimate?
A proper heat-loss calculation includes transmission and ventilation/infiltration per room. Floor area and an insulation choice do not provide those details.
Can I size a heat pump with this?
No. Lower flow temperatures reduce radiator output. Use the product output curve and a qualified room-by-room calculation.
How should I compare radiator ratings?
Compare ratings at the same temperature regime, such as 75/65/20 °C. Check the manufacturer test conditions.
What does below estimate mean?
It is a reason to check the room and radiator further, not proof that the radiator is undersized.
Sources: Radson warmteverliescalculator; Radson technische gids (voorbeeld 50/100 W/m²); Milieu Centraal over radiatorafgifte en isolatie.
Translations beyond Dutch and English are drafts and need native review.